  • IMPORTANT
    To avoid the possibility of having to reprogramme the
    switching times and temperatures, it is advisable to wait
    until the display with a flashing battery symbol changes to a
    continuous battery only display (after 30 days – Diagram D).
    In this condition the unit will remain OFF but your
    programmed settings will be held in the memory for a number of weeks. The
    two battery compartments can now be left open, to replace the batteries, for
    a
    pproximately one hour. If the compartments are left open for longer, the unit
    will revert to the factory preset times and temperatures. It may be necessary to
    reset the correct time of day after changing the batteries.
    The battery compartments are situated at the bottom of the unit (press to
    unlatch and slide down). Ensure new batteries are installed correctly. Close the
    right hand compartment first followed by the left.
    HELPFUL HINTS
    1. First/last set times The Day 1 setting cannot be programmed before
    12.00. The night setting can be programmed at whatever time you require,
    even after 12.00 midnight so long as it is not programmed more than 23 hours
    50 minutes after the Day 1 setting.
    2. Part or full day omission If during programming the Digistat, one of the
    symbols on the left hand side of the screen starts to flash, this indicates that two
    or more of the switching times have been set to the same time. This facility
    enables you to omit one or more of the switched periods. When one or more
    switching times are programmed together the later setting takes precedent. For
    example, if all four switching times were set together the Digistat would control
    continuously at the fourth (night) temperature setting .
    3. Programme sequence The Digistat will not allow you to program the
    switched periods out of sequence but will hold the times together as stated above.
    4. Reset If at any time during the programming you get confused and would
    like to start the procedure from the beginning press the SELECT and – buttons
    at the same time and hold for two seconds. This resets the Digistat to the
    factory preset times and temperatures shown in the table (overleaf).
    5. Self revert If during programming no button is pressed for between one and
    two minutes the Digistat will revert automatically to its normal operating mode.
    IMPORTANT
    This product operates on a new frequency of 433 MHz and is not inter-
    changeable with previous 418 MHz units which can be easily identified:
    433 MHz =
    Drayton brand
    418 MHz = brand
    CONFORMS TO THE ESSENTIAL REQUIREMENTS
    OF THE FOLLOWING DIRECTIVES:
    89/336/EEC Electromagnetic compatibility
    Digistat RF 2 ‘Wireless System’
    User instructions
    SCR RECEIVER
    INITIAL START UP
    IMPORTANT: ENSURE THAT THE COMMISSIONING PROCEDURE HAS
    BEEN CARRIED OUT IN ACCORDANCE WITH THE ENCLOSED
    INSTRUCTIONS.
    SCR (RECEIVER) NORMAL OPERATING MODE
    Once the ‘Wireless System’ has been commissioned, there should be little need
    for any user interface with the SCR.
    During normal operation the red and green LEDs will occasionally be on,
    these signify the following:
    Green LED
    The green LED will be on when there is a demand for heating, and off when
    there is no demand.
    Red LED
    The red LED will flash for 7 seconds, approximately every 5 minutes. This
    denotes that a radio signal is being received from the Digistat RF unit.
    SITUATIONS REQUIRING ATTENTION
    Red LED continually flashing
    This denotes that the batteries in the Digistat RF unit are approaching the end of
    their life (see ‘battery replacement’).
    Red LED continually on
    This denotes that the SCR has been unable to receive a radio signal from the
    Digistat RF unit. This may be caused by the batteries being dead (see ‘battery
    replacement’) or some temporary interference with the radio signal.
    To resend and test the signal, go to the Digistat RF unit. If the flame symbol is
    visible on the display, press the ‘–’ button until it disappears. If the flame symbol
    is not visible, press the ‘+’ button until it appears. If the radio signal has been
    successfully transmitted and received, the red LED will flash for 7 seconds then
    go off. If the red LED is still on, ‘learn mode’ may have been selected by accident
    (SCR buttons 1 and 2 pressed simultaneously). To correct, open both RF battery
    drawers and wait for the display to fade, close the right hand drawer followed by
    the left and reprogramme RF with your desired time and temperature settings.
    If the red LED is still on, there may be some other fault that will require the
    attention of a heating engineer/electrician.
    MANUAL OVERRIDE
    The heating can be manually switched on and off by using the ‘OVERRIDE’
    button on the SCR in a fault situation, even though the red LED will stay on until
    a satisfactory signal is reinstated.
    Once the SCR receives a satisfactory signal again, it will automatically reset
    itself for normal operation.
    Diagram D
    +
    Drayton
    Invensys Controls Europe
    Technical Helpline: +44 (0)845 1307722
    Customer Services: +44 (0)845 1305522
    An Invensys Product 090 795
    Invensys Climate Controls reserve the right to make changes without notice and cannot accept liability for errors. IssB
    090-795 Digistat RF2 Inst IssB 12/5/06 16:13 Page 1
Drayton Digistat RF2

Need help?

Number of questions: 6

Do you have a question about the Drayton Digistat RF2 or do you need help? Ask your question here. Provide a clear and comprehensive description of the issue and your question. The more detail you provide for your issue and question, the easier it will be for other Drayton Digistat RF2 owners to properly answer your question.

Kimberley Mawson-Scott, 2020-02-20 19:42:42 2 comments

HOW DO I OPEN TO REPLACE BATTERY

Henry Okechukwu, 2020-06-15 23:43:27

How do I open to replace the batteries

Beryl Dyer, 2020-10-26 15:21:54

We have moved into a house with a Drayton Digistat RF2 Wireless System Programmer. Unfortunately there is no user Manuel. We have tried to find it on the internet but the print is so small we can't read it and it wont print

Answer this question
Roland Linnett, 2020-11-26 15:34:05 No comments

Having trouble with setting Drayton s c r / r f 2

Answer this question
Roger Owens, 2020-11-14 18:46:17 No comments

The green light on digitsat scr does not light up when the boiler fires up.

Answer this question
Butterfield, 2020-10-19 12:42:47 No comments

How do i open the box to change the batteries

Answer this question
Dave, 2020-07-07 17:13:58 No comments

Screen blank so changed batteries but nothing has happened. No digital information just blank

Drayton Digistat RF2
Answer this question
Julia, 2020-04-28 16:05:38 1 comment

Hi after removing wallpaper the digital thermometer box on the wall has gone blank I must have got some moisture in it . Is there a way to reboot or get it to work again as the heating is no longer working! Ooops

Maggie Shaw, 2020-06-29 13:58:10

Display is incomplete

Answer this question

View the manual for the Drayton Digistat RF2 here, for free. This manual comes under the category Thermostat and has been rated by 2 people with an average of a 8.2. This manual is available in the following languages: English. Do you have a question about the Drayton Digistat RF2 or do you need help? Ask your question here

Drayton Digistat RF2 specifications

General
Brand Drayton
Model Digistat RF2
Product Thermostats
Language English
Filetype PDF

ManualSearcher.com

Looking for a manual? ManualSearcher.com ensures that you will find the manual you are looking for in no time. Our database contains more than 1 million PDF manuals from more than 10,000 brands. Every day we add the latest manuals so that you will always find the product you are looking for. It's very simple: just type the brand name and the type of product in the search bar and you can instantly view the manual of your choice online for free.

ManualSearcher.com

© Copyright 2020 ManualSearcher.com. All Rights Reserved.

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

Read more